MODEL 5008  
  COTS 8U CONFIGURABLE EUROCARD “CRATE” WITH FLUSH SUBRACK  
     
Click Image to Enlarge
Specifications (PDF)
 
 

Model 5008 is factory-configured to support 6U x 160 mm plug-in boards via dual 8-slot VME64x or CompactPCI backplanes. Its flush front subrack, 6U x 80 mm rear transition module (RTM) subrack, and quad PICMG 2.11 hot swap power supply capacity provide the user with two computer systems in a single chassis operating in standalone or redundant modes.

Forced-air cooling system begins with a front-access LRU removable “push” fan tray, with an optional rear-mounted “pull” fan tray. NOVA’s advanced baffling and plenum designs reduce internal air turbulence and vortex phenomena.

Power system features up to four (4) 3U x 8HP, 300 W (or two 6U x 8HP, 500 W) PICMG 2.11 hot swap/N+1 plug-in style modules that operate on single phase VAC or pure DC input power (separate ordering numbers).

NOVA’s μP-based System Environmental Monitor (SEM) allows the user to locally or remotely monitor and control, via onboard serial and Ethernet ports, fan speed, temperature, input/output power; additionally, there are user-definable analog and digital channels available. HTTP and SNMP protocols are included in the SEM’s firmware.

SPECIFICATIONS

  Environmental Characteristics  
     
 
Temperature, operating: -20°C to +70°C
Temperature, non-operating: -40°C to +85°C
Humidity: 10% to 95%, non-condensing
Altitude, operating: -1,500 ft. to 25,000 ft.
Altitude, non-operating: -1,500 ft. to 40,000 ft.
Vibration, operating: designed to meet MIL-STD-810G Method 514.5, Procedure I, Tranportation, Secured Cargo
Vibration, non-operating: same as operational vibration
Shock, operating: designed to meet MIL-STD-810G, Method 516.5 Procedure VI
Shock, non-operating: designed to meet MIL-STD-810G, Method 516.5 Procedures I, IV and VI
EMC: designed to meet IEEE 1101.10
ESD: MIL-STD-1686A
 
     
  Physical Characteristics  
     
 
Size: 8U H (13.97 in.) x 19 in. W x 14 in. D
Weight: Varies by configuration
Mounting configurations: 19 in. EIA-310-D rackmount or tabletop
 
     
  Electrical Characteristics  
     
 
Input Power, standard: 90 to 264 VAC @ 47-63 Hz
Inrush current: Varies with installed power supply
Input power connector: customer selectable options include:
- NEMA 5-15P
- MIL-C-26482 (MS3472 or MS3474)
- Customer selectable
Input Power, options: 115 VAC @ 60/400 Hz
24, 48 or 72 VDC
18-36 VDC
Power Consumption: Varies with installed power supply
Power Supply types: Up to four 3U x 8HP, PICMG 2.11 hot swap/N+1 modules
 
     
 
  Popular Configurations  
     
 
95-5008-21425-500 8U crate with flush 6U x 160mm subrack/6U x 80mm RTM; dual 8-slot VME64x backplanes (w/P0); quad 3U x 8HP PICMG 2.11 hot swap/N+1 power supplies w/90-264 VAC @ 47-63 Hz
input; rackmount
95-5008-21425-501 8U crate with recessed 6U x 160mm subrack and 6U x 80mm RTM; one 8-slot VME64x backplane (w/P0)
installed (upgradable to 2 backplanes); two installed 3U x 8HP, 300 W, PICMG
2.11 hot swap/N+1 power supplies w/90-264 VAC @ 47-63 Hz input; rackmount
95-5008-21625-500 8U crate with flush 6U x 160mm subrack w/6U x 80mm RTM; dual 8-slot CompactPCI 2.1R3 backplanes; quad 3U x 8HP, 300 W, PICMG 2.11
hot swap/N+1 power supplies w/90- 264 VAC @ 47-63 Hz input; rackmount
95-5008-21625-501 8U crate with flush 6U x 160mm subrack w/6U x 80mm RTM; 16-slot
CompactPCI 2.1R3/2.16 backplane (13ea payload/2ea Fabric/1ea System slot); dual 6U x 8HP, 500 W, PICMG
2.11 hot swap/N+1 power supplies w/90-264 VAC @ 47-63 Hz input; rackmount
95-5008-21725-001 8U crate with flush 6U x 160mm
subrack w/6U x 80mm RTM; 17-slot
OpenVPX Development Backplane
(14ea VPX/3ea VME64x); 1 kW fixed
internal 90-264 VAC @ 47-63 Hz input
power supply; rackmount
 
     
   
 
 
 