NOVA’s new 5112 COTS powered subrack chassis (“Crate”)
offers users a full 21 slots of Eurocard plug-in boards supporting sizes from 3U to 9U x 160mm or 220mm depths. Model 5112 as shown in the photo is configured to support twenty-one 6U x 160mm plug-in Eurocards via a recessed front subrack. Not shown in the photo is a 21-slot IEEE 1101.10/.11 compliant 6U x 80mm rear transition module [RTM] subrack.
Eurocards backplanes supported include VME64x, VXS, VPX, OpenVPX, CompactPCI©, modified custom or full custom backplane up to 21 slots. The 5112 easily supports single, dual, triple, even quadruple independent or redundant systems, each with its own power source.
Forced-air cooling system options include fixed or front-access removable
(LRU); “push” or “push-pull” configurations; tubeaxial, vaneaxial or blower
types. NOVA’s advanced baffling and plenum designs reduce internal air
turbulence and vortex phenomena that result in inefficient airflow and
selection of more expensive fan solutions than is necessary to maintain
prescribed internal operating temperature.
Power supply options includes N+1 redundant/hot swap PICMG
2.11 models. Standard input power options include
VAC single or 3Φ @ 47-63 Hz or 115 VAC @ 400 Hz; VDC options
include 24, 48 and 72.
NOVA’s μP System Environmental Monitor (SEM) allows the user
to remotely configure, monitor and control, via onboard serial
and Ethernet ports, temperature,
fan speed, input/output power. HTTP and SNMP protocols are
included in the SEM’s firmware.
SPECIFICATIONS
| |
Environmental Characteristics |
|
| |
|
|
| |
| Temperature, operating: |
-20°C to +70°C |
| Temperature, non-operating: |
-40°C to +85°C |
| Humidity: |
10% to 95%, non-condensing |
| Altitude, operating: |
-1,500 ft. to 25,000 ft. |
| Altitude, non-operating: |
-1,500 ft. to 40,000 ft. |
| Vibration, operating: |
designed to meet MIL-STD-810G Method 514.5, Procedure I, Tranportation, Secured
Cargo |
| Vibration, non-operating: |
same as operational vibration |
| Shock, operating: |
designed to meet MIL-STD-810G, Method
516.5 Procedure VI |
| Shock, non-operating: |
designed to meet MIL-STD-810G, Method
516.5 Procedures I, IV and VI |
| EMC: |
designed to meet IEEE 1101.10 |
| ESD: |
MIL-STD-1686A |
|
|
| |
|
|
| |
Physical Characteristics |
|
| |
|
|
| |
| Size: |
21 in. H x 19 in. W (17.25 chassis) x 20 in. |
| Weight: |
Varies by configuration |
| Mounting configurations: |
19 in. EIA-310-D rackmount or tabletop |
|
|
| |
|
|
| |
Electrical Characteristics |
|
| |
|
|
| |
| Input Power, standard: |
90 to 264 VAC @ 47-63 Hz |
| Inrush current: |
Varies with installed power supply |
| Input power connector: |
customer selectable options include:
- NEMA 5-15P
- MIL-C-26482 (MS3472 or MS3474)
- Customer selectable |
| Input Power, options: |
115 VAC @ 400 Hz
24, 48 or 72 VDC
18-36 VDC |
| Power Consumption: |
Varies with installed power supply |
| Power Supply types: |
Internal/fixed
Plug-in/hot swap N+1 per PICMG 2.11 |
|
|
| |
|
|
|
|
|
| |
Popular Configurations |
|
| |
|
|
| |
| 95-5112-21425-001 |
12U crate with recessed 6U x 160mm
subrack and 6U x 80mm RTM; 21-slot
VME64x backplane (w/P0); 850W internal 90-264 VAC @ 47-63 Hz
input; rackmount |
| 95-5112-21725-002 |
12U crate with recessed 6U x 160mm
subrack and 6U x 80mm RTM; dual 6-slot OpenVPX Mesh backplanes; single, internal, 1kW, 90-264 VAC @ 47-63 Hz input;
rackmount |
| 95-5112-21625-500 |
12U crate with recessed 6U x 160mm
subrack and 6U x 80mm RTM; 16-slot bridged CompactPCI© backplane; 2ea 500W, 6U x 8HP P CMG 2.11 N+1 plug-in/hot-swap,
90-264 VAC @ 47-63 Hz input power
supplies; rackmount |
|
|
| |
|
|
|
|
| |
|
|
|